Customise Consent Preferences

We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.

The cookies that are categorised as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ... 

Always Active

Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.

No cookies to display.

Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.

No cookies to display.

Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.

No cookies to display.

Performance cookies are used to understand and analyse the key performance indexes of the website which helps in delivering a better user experience for the visitors.

No cookies to display.

Advertisement cookies are used to provide visitors with customised advertisements based on the pages you visited previously and to analyse the effectiveness of the ad campaigns.

No cookies to display.

Sterilization in a flash

Sterilization, only in a flash

Pressure steam sterilizer

Styling model

It combines and styling design that is seamless from the inside out. The exterior is designed without screw eyes, allowing you to experience the charm of modern art.

Designed to make your life easier, the
Saves space and ensures greater efficiency.

Intelligent monitoring and diagnostic systems

Real-time monitoring of the entire sterilization operating system, once the fault occurs, intelligent diagnostic system can be segmented to find faulty parts, and can directly access the fault information and simple solutions, so that the accuracy of the repair to 100%, so that maintenance is more convenient. This intelligent diagnostic system is like a "real technician" with real-time diagnosis and intervention capabilities.

Good traceability

Equipped with large-capacity card reader to realize automatic storage and reading of sterilization data. It can be equipped with external thermal printer to print the sterilization data and sterilization result after each sterilization procedure.

Preheating system

Preheat standby function keeps the temperature above the minimum temperature at all times, making the program run faster and more energy efficient.

Extra large air-conditioned cooling window

260x142mm heat dissipation area, powerful and powerful, 73 layers of heat dissipation aluminum plate and 18 heat dissipation tubes, efficient condensation to ensure that the hot water is instantly cooled to room temperature and protect the drainage channel.

Novo Pro LED Data

Compact pressure steam sterilizers and their accessories help dentists and their assistants to maintain the highest level of safety and hygiene in their practices, fully complying with standards and certified by full performance and EMC safety testing systems. Type B sterilization cycles are available for sterilizing all types of packaged and unpackaged solid loads, Class A cavity loads and porous permeable loads.

0 +

Users in the country

0 term (in a mathematical formula)

patented technology

0 sky

Above fatigue test

0 months

or 2000 cycle warranty

The operation is only three clicks away.
The sterilization cycle can be completed automatically.

multilingual operating system

Intelligent Diagnostic System

11 factory preset sterilization programs and test programs

Precise touch screen control Simple, innovative and practical

Fully automated, efficient and reliable
sterilization process

Fully automated sterilization process, all stages are managed by a powerful microprocessor equipped with a real-time display of the sterilization status, automatic monitoring, traceability and management, maximizing the use of sensor performance, providing accurate data reference, the sterilization process without human intervention.

solid instruments

solid instruments

Temperature: 134°C
Sterilization type: S
Sterilization time: 10 minutes
Drying time: 9 minutes

rapid sterilization

For emergency sterilization of exposed instruments only (not for fabrics).

Temperature: 134°C
Sterilization type: S
Sterilization time: 4 minutes
Drying time: 4 minutes

porous instrument

Solid and hollow loads, cotton ball fabrics

Temperature: 134°C
Sterilization type: B
Sterilization time: 5 minutes
Drying time: 18 minutes

Wrapping Instruments

Cotton ball fabrics, packaging instruments, hollow loads

Temperature: 134°C
Sterilization type: B
Sterilization time: 18 minutes
Drying time: 18 minutes

default program

Factory preset sterilization program and test program, efficient and reliable, to meet the sterilization requirements of different loads Convenient to test the performance of the machine to ensure that the sterilization is always in good working condition.

solid instruments

solid instruments

Temperature: 121°C
Sterilization type: S
Sterilization time: 30 minutes
Drying time: 9 minutes

Rubber Products

Rubber Products

Temperature: 121°C
Sterilization type: S
Sterilization time: 20 minutes
Drying time: 9 minutes

porous instrument

Cryogenic textiles, packaging instruments, mixed loads (packed/unpacked)

Temperature: 121°C
Sterilization type: B
Sterilization time: 20 minutes
Drying time: 18 minutes

Wrapping Instruments

Against a virus similar to mad cow disease

Temperature: 121°C
Sterilization type: B
Sterilization time: 30 minutes
Drying time: 18 minutes

Built-in open tank

3.5L large-capacity water tank, can meet the water needs of 5 sterilization cycles, can be monitored and easy to clean the full open tank, easy to check the water quality inside the tank for daily cleaning and disinfection.

Water supply method

Water Filling Function Manual (standard)/Full Automatic (optional) The sterilizer is equipped with a pump-controlled automatic water filling system with a water level sensor that automatically stops filling when the tank is full.

Water quality monitoring function (optional)

Increase the water quality monitoring sensor, effective real-time control of water quality, thus avoiding pipeline blockage due to water impurities after high temperature calcification, prolonging the service life of the sterilizer.

Average water consumption

Novo Pro18L: 0.15L (min) 0.26L (max)
Novo Pro 23L: 0.17L (min) 0.31L (max)

hull

Simple manual door adjustment design, 5 seconds to easily complete the adjustment of the door tightness new door safety lock ergonomic design, easier to open and close, hand-operated mechanical door locks, intelligent electronic door locks, security pressure door locks triple door locks protection allows you to rest easy.

mechanical lock

Electronic sensor switch

pneumatic lock

Prevents the door from opening automatically during the sterilization process, protecting the user's personal safety.

Brackets/pallets

The trays can carry three or five tiers at the same time and can be interchanged by rotating 90 degrees. Users can choose according to the number of different sterilized instruments.

Stainless Steel Bracket

23L: 410*205*200 mm
18L: 310*205*200 mm

Stainless Steel Bracket

23L: 380*190*20 mm
18L: 285*190*20 mm

Instrument case (optional)

Examples: mirrors, probes, etc.
205 X 140 X 32mm

Instrument case (optional)

Examples: mirrors, probes, etc.
180 X 125 X 20mm

Pot Size

23L/18L
23L
18L

Mounting Dimensions

Technical Parameters

Applicable Voltage

220-240 VAC-50/60Hz, single-phase voltage

rated voltage

220V, 50Hz

Maximum current

10A

highest altitude

Altitude 2000 meters, above 2000 meters please contact local dealer

Maximum working pressure

2.5 Bar (250 kPa)

Minimum working pressure

-0.9 Bar(-90 kpa)

Minimum atmospheric pressure

0.7bar

highest temperature

<145°C

Overall dimensions

585x438x405mm (Novo Pro18L)
685x438x405mm (Novo Pro 23L)

full load weight

50 kg (Novo Pro 18L)
60kg (Novo Pro 23L)

safety threshold

2.45 bar (in accordance with YY0154-2013 and YY/T0157-2013)

vacuum

>-0.08Mpa

noise level

< 80 DB

Total volume of pot

245 mm x D355 mm (Novo Pro 18L)
245 mm x D445 mm (Novo Pro 23L)

Available pot volume

198 mm x 204 mm x 319 mm (Novo Pro 18L)
198 mm x 204 mm x 385 mm (Novo Pro 23L)

Steam Filter

Filtering efficiency of particles above 0.3um is not less than 99.5%.

Water quality requirements

EC (conductivity <15uS/cm)

Average water consumption per cycle

Novo Pro 18L: 0.15L (min) 0.26L (max)
Novo Pro 23L: 0.17L (min) 0.31L (max)

Tank volume

Water purification tank 3.5L

Declaration of Conformity

YY/T0646-2015

Small steam sterilizer Automatic control type